SOLVENT WASTE DISPOSAL

products for the temporary collection & storage of hazardous waste in the lab.
Laboratory Services

HPV Decontamination
Hydrogen Peroxide Vapour Decontamination is ideal for biological safety cabinets, CO2 incubators, pass through hatches, isolators, robotics as well as a wide range of of other laboratory and related equipment.
Mechanical Testing
Professional, on-site testing and certification service including, but not limited to the following:
• Cleanrooms
• Biological Safety Cabinets
• Laminar Flow Equipment
• Chemical Fume Hoods
• Surgical Suites
• Isolation Rooms
• Pharmaceutical Isolators
• Cytotoxic Cabinets
• General HEPA filtered Air-handling Systems.
| SAFE-HOOD | | Print | |
|
| Laboratory Fume Hood | SAFE-HOOD 75 | SAFE-HOOD 120 |
SAFE-HOOD 165 |
| Work chamber (wxdxh) mm | 550 x 550 x 600 | 1000 x 550 x 600 | 1450 x 550 x 600 |
| Overall dimensions (wxdxh) mm | 750 x 720 x 1200 |
1200 x 720 x 1200 | 1650 x 720 x 1200 |
| Work surface | SS AISI 304 or Polypropylene (not included) | SS AISI 304 or Polypropylene (not included) | SS AISI 304 or Polypropylene (not included) |
| Treated air volume (M3/h) |
300 | 550 | 800 |
| Average front barrier speed (M/sec) | >0,5 (set point 0,50 m/s) |
>0,5 (set point 0,50 m/s) | >0,5 (set point 0,50 m/s) |
| Power supply (Hz) | 230V - 50 Hz | 230V - 50 Hz | 230V - 50 Hz |
| Power requirement (W) | 420 | 800 | 1175 |
| Lightning (Lux) | >400 | >400 | >400 |
| Control Panel | Soft-touch control panel with fan on-off switch; alarm mute, separate main switch | Soft-touch control panel with fan on-off switch; alarm mute, separate main switch | Soft-touch control panel with fan on-off switch; alarm mute, separate main switch |
| Functions and Alarms | Continuous front barrier average speed display; display in M/sec or fmp; alarm LEDs for fan(s), airflow, front window position, filter efficiency | Continuous front barrier average speed display; display in M/sec or fmp; alarm LEDs for fan(s), airflow, front window position, filter efficiency | Continuous front barrier average speed display; display in M/sec or fmp; alarm LEDs for fan(s), airflow, front window position, filter efficiency |
| FILTERS - Induction Fan(s) (qty./W) |
1/375 W 2 | 2/375 W 3 | 3/375 W |
| FILTERS - Main filter 12 kg (qty.) |
1 | 2 | 3 |
| FILTERS - Exhaust safety filter 4 kg (qty.) |
1 | 2 | 2 |
| FILTERS - Prefilter (qty.) | 1 | 2 | 3 |
| Construction: Main body | Epoxy painted cold rolled steel | Epoxy painted cold rolled steel | Epoxy painted cold rolled steel |
| Construction: Lateral windows |
Safety glass |
Safety glass | Safety glass |
SAFE-HOOD Fume Hood Cabinet Image Gallery:
|
|
|
|
> Quote Request < for the Bio-Cabinets SAFE-HOOD Fume Hood Cabinet.
|
Molecular filtration ductless fume enclosure applications:
- Chemical, analytical and research laboratories
- Schools and universities
- Anatomo-pathology
- Micro welding
- Forensics
SAFE-HOOD Fume Hood Cabinet Specifications. (POP UP)


Fume Hood Cabinets